4.2.7 RAID Groups Options
Before RAID Groups are created, the following options can be modified:
FIELD DEFINITION
RAID Group
Label
Enter an identifiable name for the RAID group. This value can be any string (up to 8 characters
including blank spaces) to help users identify this volume.
RAID Group
Select a Group ID from the available ID list. The maximum number of RAID Groups per controller
is 8. Group ID can be any number between 0 and 7.
Configuration
Select which RAID level is to be used to configure these members:
• Contiguous (for virtual disk, JBOD Mode).
• Concatenated (for multiple concatenated segments, Spanning Mode)
• Striped (for RAID 0)
• Mirrored (for RAID 1)
• Mirrored Striped (for RAID 10)
• Parity RAID (for RAID 5)
Capacity
Select a value to define the total usable capacity of the RAID Group or manually enter the volume
size in gigabytes (GB). Selecting MAX will create the largest RAID set possible with the drive(s)
selected.
Chunk Size
Select a value to define the chunk size (stripe size) for performance tuning. In general, large stripe
sizes are best for large files that are accessed sequentially (for example, media streaming files) and
smaller sizes are better for randomly accessed data like databases. This parameter is not used for
Contiguous, Concatenated, and Mirrored configurations.
Rebuild Priority
Select a value to identify how quickly the controller should rebuild data on a disk after a hardware
failure. A value of 1 is the lowest priority and will take the longest to rebuild. A value of 10 is the
highest priority and will rebuild the fastest. Higher priority will require more CPU resources, which